Description
Defining the amount of energy available in a battery is a complex task since
battery age, discharge current and temperature all influence the actual battery
capacity. High performance measuring circuits, along with complex software
algorithms, are used to exactly determine the remaining battery capacity. A new
shunt selection feature enables the LinkLITE to measure
currents up to 1,000Amps respectively.
The LinkLITE selectively displays voltage, charge and
discharge current, consumed amphours and remaining battery capacity. Using a
clear backlit LCD Display and an intuitive user interface, all parameters can be
recalled with just a button press. A second battery input is also provided to
monitor voltage on a second battery.
It is equipped with an internal programmable alarm relay, to run a generator
when
needed or to turn off devices when the battery voltage exceeds programmable
boundaries.
Performance Features
- Read your battery bank like a fuel gauge
- Provides critical information about the status of your battery bank
- Displays voltage, current, consumed amphours and remaining battery
capacity
- Secondary battery bank voltage monitoring
- Auto sensing battery voltage inputs
- Large backlit LCD Display
- Quick nut mounting construction
- Programmable alarm relay
- Shunt selection capability enables flexible system integration
- Splash proof frontpanel
- 500 Amp shunt included
- CE and e-mark certified
Specifications
Electrical Specifications |
|
|
|
Supply voltage range |
9 to 35 Vdc |
Supply current * |
|
· @ Vin = 12 Vdc |
9 mA |
· @ Vin = 24 Vdc |
7 mA |
Input voltage range |
|
· Main battery |
0 to 35 Vdc |
· Auxiliary battery |
2 to 35 Vdc |
Input current range** |
-999 to +999A |
Battery capacity range |
20 to 999A |
Readout resolution |
|
· Voltage (0 to 35V) |
± 0.1V |
· Current |
0 to 99A (± 0.1A) |
· Current |
100 to 999A (± 1A) |
· Amphours |
0 to 99Ah (± 0.1Ah) |
· Amphours |
100 to 999Ah (± 1Ah) |
· State-of-charge |
± 1% |
Voltage measurement accuracy |
± 0.3% |
Current measurement accuracy |
± 0.4% |
|
|
General Specifications |
|
|
|
Operating temperature*** |
-20 to 50°C |
Battery monitor dimensions |
|
· Front panel |
∅ 2.54” (64mm) |
· Body diameter |
∅ 2.05” (52mm) |
· Total depth |
∅ 3.11” (79mm) |
Shunt dimensions |
|
· Footprint |
1.77 x 3.43” (45 x 87mm) |
· Height |
0.67” (17mm) base / 1.38” (35mm) terminal bolts |
Weight |
|
· Battery monitor weight |
0.21 lb (95 g) |
· Shunt weight |
0.32 lb (145 g) |
Warranty |
One year |
Part Numbers |
84-2030-00 |
|
|
Accessories |
|
|
|
Connection kit - 50ft (15m) |
854-2021-01 |
|
|
Regulatory & Environmental Compliance |
|
|
EMC Directive 2004/108/EC (EN61000-6-2 and -6-3).
Automotive EMC Directive 95/54/EC. RoHS Directive 2002/95/EC |
|
|
* Measured with backlight and alarm relay turned off. |
** Only available when optional temperature sensor is
connected. |
*** Depends on selected shunt. With standard delivered
500A/50mV shunt (350A continuous), the range is limited from -600 to +600A. |
Note: Specifications subject to change without notice. |
Document Type |
Document Name |
Last Updated |
File Type |
Size |
Download |
Owners Manual |
LinkLITE Battery Monitor Operation Manual |
7/11/2008 |
|
500 KB |
|
Data Sheet |
LinkLITE Battery Monitor Datasheet |
9/15/2008 |
|
548 KB |
|
Warranty |
LinkLITE Battery Monitor Warranty |
7/11/2008 |
|
209 KB |
|
Other |
LinkLITE Battery Monitor Addendum |
7/11/2008 |
|
95 KB |
|
Other |
LinkLITE Battery Monitor Connection Kit |
7/11/2008 |
|
170 KB |
|
Other |
LinkLITE Battery Monitor Installation Guide |
7/11/2008 |
|
237 KB |
|