Electrical Specifications |
|
Output power |
|
1800 watts |
|
Surge rating |
|
2900 watts |
|
Peak output current |
|
20 A |
|
Output voltage (at no load) |
|
230 VAC +/-3% |
|
Output voltage (over full load and battery
voltage range) |
|
230 VAC RMS -10%/+4% |
|
Output frequency |
|
50+/-0.05 (crystal controlled) |
|
Output waveform |
|
True sine wave (<3% THD) |
|
Peak efficiency (12 V/24 V) |
|
90% |
|
No load power draw (search mode) |
|
<1.5 W |
|
No load power draw (idle mode) |
|
<22 W |
|
Input voltage range (12 V/24 V) |
|
10 - 16 VDC / 20 - 32 VDC |
|
Transfer relay rating (hardwire/transfer
relay models) |
|
10 A |
|
Transfer time AC to inverter and inverter
to AC |
|
Max 2 cycles (typically 1 cycle) <2.5
seconds with Powersave "ON" |
|
General Specifications |
|
Operating temperature range |
|
32 F - 140 F (0°C - 60°C) |
|
Storage temperature range |
|
-22°F - 158°F (-30°C - 70°C) |
|
|
|
Hardwire |
|
AC output types |
|
Hardwire with transfer relay |
|
|
|
Schuko AC receptacle |
|
LCD display panel |
|
Removable; can be mounted remotely
(requires remote interface kit) |
|
Recommended DC fuse (12 V model) |
|
300 A (depending on applicable
installation codes) |
|
Recommended DC fuse (24 V model) |
|
100 A (depending on applicable
installation codes) |
|
Dimensions (H x W x D) |
|
4.5 x 11.0 x 15.4" (115 x 280 x 390 mm) |
|
Weight |
|
16.5 lb (7.5 kg) |
|
Warranty |
|
Two year |
|
Part numbers |
|
806-1870 (12 V/230 SCHUKO) |
|
|
|
806-1873 (12 V/230 Hardwire) |
|
|
|
806-1874 (12 V/230 Hardwire & transfer
switch) |
|
|
|
806-1880 (24 V/230 SCHUKO) |
|
|
|
806-1883 (24 V/230 Hardwire) |
|
|
|
806-1884 (24 V/230 Hardwire & transfer
switch) |
|
|
|
808-1800 (Remote interface kit) |
|
Regulatory Approvals |
|
CE Mark - Low Voltage Directive
(EN50091-1) |
|
EMC Directive (EN50091-2) |
|
e-Mark - Automotive EMC Directive 95/54/EC |
|
Note: Specifications subject to change