Heavy Duty Series
• Designed for powering 12 and 24 VDC
communication/navigation equipment aboard
commercial vessels where reliability is the primary consideration.
• Input voltage 115 or 230 VAC selected by slide switch on the front panel.
• Excellent Regulation and Ripple Spec: Output voltage maintained within 1%
under all
line and load conditions within rating; Ripple is less than 40 mV P-P. (12
volt) or
70 mV P-P (24-volt)
• Polyurethane conformal coated PC board and corrosion resistant heavy duty
aluminum
case with integral shock mounts assures survival in hostile environments
• Heat generated by semi-conductors is extracted and dissipated by large heat
sink fins that
maximize air contact for cool operation and long life of components.
• Supply and Load Circuit Protection: overvoltage, current limit; (set @ 105% of
intermittent
rating), thermal overload and input/output fusing.
• Thermally activated cooling fan on “CD” units.
Specifications
Model
|
Nominal
|
Output Amperage
|
Case
Size Ref.
|
Weight
|
Input
|
VAC
|
Intermittent
|
Continuous
|
Lbs.
|
Kg.
|
12 Volt Output |
115-12-8 |
115
|
230
|
8
|
5
|
P-2
|
10
|
4.5
|
115-12-20A |
115
|
230
|
20
|
8
|
P-3
|
20
|
9.1
|
115-12-35CD |
115
|
230
|
35
|
35
|
P-5
|
32
|
14.6
|
Case Size Reference
|
inches |
Centimeters |
H |
W |
D |
H |
W |
D |
P-1 |
6.0 |
4.6 |
8.5 |
15.2 |
11.7 |
21.6 |
P-2 |
5.7 |
4.8 |
16.3 |
14.5 |
12.2 |
41.4 |
P-3 |
6.5 |
9.5 |
14.0 |
16.5 |
24.1 |
35.6 |
P-4 |
6.5 |
13.0 |
18.75 |
16.5 |
33.0 |
47.6 |
Specifications
Input Range
105-125/210-250 VAC (selectable), 50-60 Hz; Derate to 50% output below
110 and 220 VAC
Operating Temperature
Standard Units
0-50˚ C, Derate Linearly From 100% @ 40˚ C To 50% @ 50˚ C Thermal shutdown @ 85˚
C Case temperature
C.D. Units
0-65°C, Derate Linearly From 100% @ 50˚ C To 50% @ 65˚ C Thermal Shutdown @ 85˚
C Case temperature
Duty Cycle
Intermittent: 20 minutes max on time, 20% duty
Continuous: 24 Hours/Day 100% Duty
Options
- Modify for use as a Battery Charger
- Output voltage adjust (see Output Voltage for range)
- Transfer relay for back-up battery in event of power failure (ERC option)
Output Voltage
12 V Models: 13.6 VDC (Internally adjustable 12.6-14.5 VDC)
Ripple: 40mV P-P (@ 110-125 / 220-250 VAC input)
24 V Models: 24.5 VDC (Internally adjustable 21-27.5 VDC)
Ripple: 70mV P-P (@ 110-125 / 220-250 VAC input)
Regulation All Models: 1% Line and Load (@ 110-125 / 220-250
VAC input)
Mechanical
- Powder coated aluminum heat sink case
- Front panel terminal block
- Heavy duty mounting flange
- Conformal coated PC board
Manual for