These heavy duty isolators
allow charging multiple batteries automatically from one or two alternators, and
prevent discharge or "dumping" of one battery into another. Each battery is
charged according to its need without overcharging.
Rated for 12-48 volt
negative ground DC systems. Feature conservatively rated diodes and a rustproof
anodized aluminum heat sink case. Models are available for 70, 120 and 165 amp
alternators.
Features:
-
Heavy duty construction
-
Rated for systems up to
48 volts DC
-
Rust-proof anodized
aluminum case
-
Stainless steel mounting
hardware provided
-
Protective covers
provided for terminals
Performance Specifications
Operating
temperature: -40 to +80° C
Duty cycle: Continuous rating to 50° C Derate linearly to 70% @ 80° C
Temp. rise: 95° C at full rated current (mount vertically for optimum
cooling)
Voltage drop: At 50% load 0.7V - At full load 0.9V
Model |
Alternator
|
Battery
|
Max
Amperage
|
Weight
|
Dimensions
|
|
Sources
|
Bank
|
Input
Capacity
|
Lbs
|
Kg
|
L
|
W
|
H
|
|
1/2/70 |
1
|
2
|
70
|
2
|
0.9
|
3.25
|
4.5
|
3.1
|
in |
|
|
|
|
|
|
8.3
|
11.4
|
7.9
|
cm |
1/3/70 |
1
|
3
|
70
|
2
|
0.9
|
3.25
|
4.5
|
3.1
|
in |
|
|
|
|
|
|
8.3
|
11.4
|
7.9
|
cm |
2/3/70 |
2
|
3
|
70
|
4
|
1.8
|
6.5
|
4.5
|
3.1
|
in |
|
|
|
|
|
|
16.5
|
11.4
|
7.9
|
cm |
1-2-120 |
1
|
2
|
120
|
3
|
1.4
|
6.5
|
4.5
|
3.1
|
in |
|
|
|
|
|
|
16.5
|
11.4
|
8
|
cm |
1-3-120 |
1
|
3
|
120
|
3
|
1.4
|
6.5
|
4.5
|
3.1
|
in |
|
|
|
|
|
|
16.5
|
11.4
|
8
|
cm |
2-3-120 |
2
|
3
|
120
|
5
|
2.3
|
12.5
|
4.5
|
3.1
|
in |
|
|
|
|
|
|
30.5
|
11.4
|
7.9
|
cm |
1-3-165 |
1
|
3
|
165
|
5
|
2.3
|
9
|
4.5
|
3.1
|
in |
|
|
|
|
|
|
22.9
|
11.4
|
8
|
cm |
Application Note:
Battery Isolators may also be used to facilitate N+1 parallel/redundant
operation of power supplies. Contact factory. |