Newmar ES-3 AC/DC Master Control Panel
Locating all AC and DC
functions on one panel provides a vessel with a central load distribution and
monitoring center. Features
common to all models include:
• Complete metering of voltage and current on AC and DC systems. Back-lit analog
meters are standard, digital optional .
• AC master breaker(s) with reverse polarity warning light.
• Power "on" indicator lights on all circuits.
• four battery bank voltage test switch
• Deluxe label set (LS-III) included, 206 functions.
• Multiple position ground bus bar
• Rating 115/230 VAC, 65 VDC
ES-3
This panel combines AC and DC control into one compact panel.
See list of specifications at bottom of page.
13.7W” X 10””H X 4” D 10 lbs
(34.8 X 25.4 X 10.2 cm 4.5Kg.) |
|
ES-4
Large 3 1/2" scale meters
and an ample circuit breaker capacity makes this the panel of choice for
boats in the
35'-45' range.
Circuit specifications listed at bottom of page.
17”W X 12”H X 4” D 12 lbs
(43.2 X 30.5 X 10.2 cm 5.5Kg.)
|
ES-5
Exceptional yachts require an extraordinary panel which incorporates all the
aspects of the vessel's electrical system. The ES-5 is such a panel. In addition
to its large DC circuit capacity, the AC section includes two load groups and a
source selector switch for two shore power lines and a 15kW generator. Pre-heat
and start-stop controls are standard. additional system capacity can be obtained
by incorporating model ES-6 or ES-7 above.
20" W x 15" H x 6" D 20
Lbs.
(50.8 X 38.1 X 15.2 cm, 9.1Kg.)
Model
|
DC Circuits |
AC Circuits |
ES-3 |
16
Breaker capacity, 12 Installed standard; 2-5A, 3-10A, 4-15A, 3-20A or
specify |
Master (D.P.)
30 amp standard 50 amp* optional, plus 6 S.P. branch capacity, 5 installed
standard; 1-10A,15A, 2-20A or specify |
ES-4 |
20
Breaker capacity, 16 Installed standard;3-5A, 3-10A, 5-15A, 5-20A or specify |
Master (D.P.)
50 amp* standard plus 8S.P. branch capacity,6 installed standard; 1-10A,
3-15A, 2-20A or specify |
ES-4SS |
Same as
above with 7.5 kW, three position (Shore-Off-Gen) ship shore selector switch
installed. Special Order Only. |
ES-5 |
Master
plus 24 breaker capacity, 20 installed standard;3-5A, 4-10A, 7-15A, 6-20A or
specify |
Two load
groups each consisting of: Master breaker(D.P.) 50 amp*standard plus 10 S.P.
branch capacity, 8 installed standard;2-10A, 3-15A, 3-20A or specify |
*Note
(For panels used in 230 VAC applications): 50 amp Master OK for use on 230
VAC line-to-line systems. Not for 230 VAC line-to-neutral systems.
|
Installation Dimensions
Model |
Panel Size |
Cut Out |
(W x H) Inches |
(W x H) Centimeters |
(W x H) Inches |
(W x H) Centimeters |
ES-1 |
10 x 15 |
25.4 x 38.1 |
14 X 9 |
35.6 X 22.9 |
ES-3 |
13.7 x 10 |
34.8 x 25.4 |
8.8 X 13 |
22.4 X 33 |
ES-4 |
17 x 12 |
43.2 x 30.5 |
10.8 X 16.8 |
27.4 X 42.7 |
ES-5 |
20 x 15 |
50.8 x 38.1 |
13 X 19 |
33 X 48.3 |
ES-6D |
5.25 x 15 |
13.3 x 38.1 |
13 X 4.5 |
33 X 11.4 |
ES-7A & 7D |
5.25 x 15 |
13.3 x 38.1 |
13.8 X 4 |
35.1 X 10.2 |
Model |
DC Circuits |
AC Circuits |
ES-1 |
100A master plus 22 single pole breaker
capacity, 20 installed standard, 3-5A, 5-10A, 6-15A, 6-20A |
|
ES-3 |
16 Breaker capacity, 12 Installed standard;
2-5A, 3-10A, 4-15A, 3-20A or specify |
30 amp master standard 50 amp optional, plus 6 S.P. branch capacity, 5
installed standard; 1-10A, 15A, 2-20A or specify |
ES-4 |
20 Breaker capacity, 16 Installed standard; 3-5A, 3-10A, 5-15A, 5-20A or
specify |
50 amp master standard plus 8S.P. branch capacity, 6 installed standard;
1-10A, 3-15A, 2-20A or specify |
ES-4SS |
Same as above with 7.5 kW, three position
(Shore-Off-Gen) ship shore selector
switch installed. Special Order Only. |
ES-5 |
Master plus 24 breaker capacity, 20 installed standard; 3-5A, 4-10A,
7-15A, 6-20A or specify |
Two load groups each consisting of: Master breaker (D.P.) 50 amp* standard
plus 10 S.P. branch capacity, 8 installed standard; 2-10A, 3-15A, 3-20A or
specify |
ES-6D |
75A master plus 10 single pole breaker
capacity, 8 installed standard, 1-5A, 2-10A, 4-15A, 1-20A |
|
ES-7A |
|
50A double pole master plus 16 single pole breaker capacity, 12 installed
standard, 2-10A, 5-15A, 5-20A |
ES-7D |
100A master plus 16 single pole breaker capacity, 12 installed standard,
2-5A, 3-10A, 5-15A, 2-20A |
|